UPS manufacturer good quality and best price 10kva-40kva 3/1 ups
Main Features
· Double conversion topology technology, pure sine wave output.
· Advanced DSP digital control technology.
· Environmental Friendly and energy saving, as the input Voltage harmonic is ≤2% R load,≤5% RCD load .
· Wide input voltage and frequency range,400VAC(three phase with ground) ,Line mode 45~55Hz or 55~65Hz follow .
· 0ms Line-Bat transfer , ensure the safety and reliablity of load.
· ECO mode optional, reduce the UPS power consumption.
· Low audible noise (below ≤70dB), will not affect your daily life.
Product Details
Specfictations
Main Features
· Double conversion topology technology, pure sine wave output.
· Advanced DSP digital control technology.
· Environmental Friendly and energy saving, as the input Voltage harmonic is ≤2% R load,≤5% RCD load .
· Wide input voltage and frequency range,400VAC(three phase with ground) ,Line mode 45~55Hz or 55~65Hz follow .
· 0ms Line-Bat transfer , ensure the safety and reliablity of load.
· ECO mode optional, reduce the UPS power consumption.
· Low audible noise (below ≤70dB), will not affect your daily life.
Product Details
Specfictations
Model | 31 10K | 31 15K | 31 20K | 31 30K | 31 40K |
Phase | 10KVA/8KW | 15KVA/12KW | 20KVA/16KW | 30KVA/24KW | 40KVA/32KW |
Input | |||||
Rate voltage | 400VAC(three phase with ground) | ||||
Voltage range | 165~280Vac(phase)/285~485Vac(line) | ||||
Frequency range | 50/60Hz±10% | ||||
Output | |||||
Rate voltage | 220/230/240VAC(single phase) ±1% | ||||
Frequency range | Line mode 45~55Hz or 55~65Hz follow;BAT mode 50Hz or 60Hz | ||||
Frequency regulation | ±1% | ||||
Voltage harmonic | ≤2% R load; ≤5% RCD load | ||||
Crest ration | 3:01 | ||||
Transfer time | 0ms | ||||
Transient response | 0%~100%(R load)≤±5%;20%~100%(RCD load)≤±3% | ||||
Transient recovery | 0%~100%(RCD load)<60ms recover to 90% | ||||
Over load | 0%~110% normal;110%~150% 10~1min;load>160%,200ms; (transfer to bypass and alarm) | ||||
Output short | 60~100ms | ||||
Efficiency | ≥ 88% | ≥ 90% | |||
Grid rectifier | |||||
rectifier | 6 pulse | ||||
Charge voltage | 290VDC~435VDC adjustable | ||||
Charge current | Default 10A,max 40A | ||||
BAT NO. | 29/30/31/32 adjustable,default 32 | ||||
Size(length*width*height)and weight | |||||
Size (mm) | 656*405*817 | 950*560*1333 | |||
Weight (kg) | 118 | 120 | 145 | 193 | 278 |
IP grade | IP21 | ||||
Environment | |||||
Temperature/ humidity | 0ºC~40ºC;20%~95% | ||||
Audible noise | ≤ 70dB | ||||
Communication | RS-232/USB/SNMP card |